High Density Housing / Commercial - Addition / Alteration - Elevator modernization Interior alterations to provide elevator modernization to the existing addressable two-stage fire alarm system to incorporate emergency recall of four elevators to meet the requirements of CSA-B44 in this existing 23-storey commercial (hotel) building on this site. Scope of work: - Reprogram and upgrade existing addressable two-stage fire alarm control panel to suite the automatic emergency elevator recall function. - Modify existing fire alarm annunciator to show additional automatic emergency elevator recall zones. - Add addressable smoke detectors, heat detectors and fire alarm strobes. - Install new elevator controllers, new elevator machines, operating fixtures, lobby emergency phone panel, relays and reprogram existing addressable FAS initiation devices to allow for activation of the automatic emergency elevator recall sequence. ******THIS PERMIT HAS BEEN REVIEWED AND ISSUED UNDER THE REQUIREMENTS OF VBBL 2019 ******** Building Review Branch Notes: - Elec. B submitted by H. Joo, P. Eng. - Schedule A & Arch. B for elevating devices submitted by W. K. Chang, P. Eng. - Arch. B submitted by J. Emery. - Automatic emergency recall (main - ground floor, alternate - 4th floor)

550 W HASTINGS STREET, Vancouver, BC V6B 1L6 · Vancouver, BC